三菱伺服驱动器维修当中,到是不怎么涉及到三菱伺服驱动器发热量计算,但是在设置控制柜的时候,却是需要设计发热量的,怎么样计算三菱伺服驱动器的发热量呢,三菱官方实际上是有说明的:
伺服放大器 3020
|
伺服电机
|
(注1) 电源
设备容量 [kVA]
|
(注2)伺服放大器散热量[W]
|
散热所需面积 [m2]
|
|
额定输出时
|
伺服关闭时
|
|
|
|
|
MR-J4-10A
|
HG-MR053
|
0.3
|
25
|
15
|
0.5
|
HG-MR13
|
0.3
|
25
|
15
|
0.5
|
|
HG-KR053・13
|
0.3
|
25
|
15
|
0.5
|
|
MR-J4-20A
|
HG-MR23
|
0.5
|
25
|
15
|
0.5
|
HG-KR23
|
0.5
|
25
|
15
|
0.5
|
|
MR-J4-40A
|
HG-MR43
|
0.9
|
35
|
15
|
0.7
|
HG-KR43
|
0.9
|
35
|
15
|
0.7
|
|
MR-J4-60A
|
HG-SR52
|
1.0
|
40
|
15
|
0.8
|
HG-SR51
|
1.0
|
40
|
15
|
0.8
|
|
MR-J4-70A
|
HG-MR73
|
1.3
|
50
|
15
|
1.0
|
HG-KR73
|
1.3
|
50
|
15
|
1.0
|
|
MR-J4-100A
|
HG-SR102
|
1.7
|
50
|
15
|
1.0
|
HG-SR81
|
1.5
|
50
|
15
|
1.0
|
|
MR-J4-200A
|
HG-SR152
|
2.5
|
90
|
20
|
1.8
|
HG-SR202
|
3.5
|
90
|
20
|
1.8
|
|
HG-SR121
|
2.1
|
90
|
20
|
1.8
|
|
HG-SR201
|
3.5
|
90
|
20
|
1.8
|
|
MR-J4-350A
|
HG-SR352
|
5.5
|
130
|
20
|
2.6
|
HG-SR301
|
4.8
|
120
|
20
|
2.4
|
|
MR-J4-500A
|
HG-SR502
|
7.5
|
195
|
25
|
3.9
|
HG-SR421
|
6.3
|
160
|
25
|
3.2
|
|
MR-J4-700A
|
HG-SR702
|
10
|
300
|
25
|
6.0
|
注 1. 请注意电源设备容量根据电源阻抗的变化而变化。该值时不使用功率因数改善AC电抗和功率
因数改善DC电抗的情况。
2. 伺服放大器的发热量不包括再生时的发热。再生选件的发热情况请根据11.2节计算。
可以参考以上参数进行设计考虑